 For this, the rule from above can be applied, even for people for weigh under 100KG (220 lbs) f. For this, the rule from above can be applied, even for people for weigh under 100KG (220 lbs) f.
  
-//It's recommendable to upgrade your motor phase cables connectors to more resilient ones once you go over 900W Peak. //+//Generally it's recommendable to upgrade your motor phase cables connectors to more resilient ones.//
  
-//(For "XT150" 6mm bullet connectors f. ex. or just solder the motor cables together)//+//(For "XT150" 6mm bullet connectors, MR60 or MT60 f. ex. or just solder the motor cables together)//
  
 ^Amperes (Current Limit)^Watts| ^Amperes (Current Limit)^Watts|
Line 389: Line 389:
 |50|1400| |50|1400|
 |**55 (Standard)** |**1540** | |**55 (Standard)** |**1540** |
-|60|160|+|60|1600|
 |__**65 (max. rec.)**__ |**__1820__ ** | |__**65 (max. rec.)**__ |**__1820__ ** |
  
-As for the current limit it'explicitly recommended to let the peak at a max. of 65A (max. ~1.8KW) or below it.+As for the current limit it's recommended to let the peak at a max. of 65A (max. ~1.8KW) or below it.
  
 Also here it's adviceable to maintain the current based on your weight and to your routes, as this can expand prolongevity of the components and also minimizes the battery draw. Also here it's adviceable to maintain the current based on your weight and to your routes, as this can expand prolongevity of the components and also minimizes the battery draw.
Line 398: Line 398:
 If it so happens that you're satisfied with 55A already, then you don't need to do more tweaking. But if it may seem much to you, then you can step down the Amperes bit by bit until you're satisfied with the results. If it so happens that you're satisfied with 55A already, then you don't need to do more tweaking. But if it may seem much to you, then you can step down the Amperes bit by bit until you're satisfied with the results.
  
-Otherwise if you aren't satified with 55A you can rise up slowly until 65A.+Otherwise if you aren't satified with standard 55A you can rise up slowly until 65A.
  