====== Ninebot ESx/Max Error Codes ====== | ====== Ninebot ESx/Max Error Codes ====== | ||
- | ^Code ^Description | + | ^Code ^Description |
- | |10|No communication with BLE board | + | |10|Communication Failure between Dashboard and ESC. |
- | |11|Motor phase A current out of range | | | + | |11|Motor phase A current out of range | |Hardware error|3| |
- | |12|Motor phase B current out of range| | | + | |12|Motor phase B current out of range| |
- | |13|Motor phase C current out of range| | + | |13|Motor phase C current out of range| |
- | |14|Throttle handle position out of range|Throttle might be stuck, faulty or disconnected| | + | |14|Throttle handle position out of range|Throttle might be stuck, faulty or disconnected|Hardware error|3| |
- | |15|Brake handle position out of range|Brake handle might be stuck, faulty or disconnected| | + | |15|Brake handle position out of range|Brake handle might be stuck, faulty or disconnected|Hardware error|3| |
- | |18|Motor Hall sensors stuck at 0/1|Check 2×4 connector between ESC and motor; [[https:// | + | |16|Internal Battery change MOS abnormal| |Hardware error|3| |
- | |19|Internal battery voltage out of range| | | + | |17|External battery change MOS abnormal| |Hardware error|3| |
- | |20|External battery voltage out of range| | | + | |18|Motor Hall sensors stuck at 0/1|Check 2×4 connector between ESC and motor; [[https:// |
- | |21|No communication with internal BMS|Check data connector between internal battery and ESC, replace the battery| | + | |19|Internal battery voltage out of range| |
- | |22|Internal BMS config invalid|Replace internal BMS or battery; [[https:// | + | |20|External battery voltage out of range| |
- | |23|Internal BMS not activated (has default S/ | + | |21|No communication with internal BMS|Check data connector between internal battery and ESC, replace the battery|Battery mod warning|2| |
- | |24|Supply voltage out of range| | | + | |22|Internal BMS config invalid|Replace internal BMS or battery; [[https:// |
- | |26|Flash save error|Try to flash ESC with ST-Link ([[https:// | + | |23|Internal BMS not activated (has default S/ |
- | |27|ESC config invalid|Try to flash ESC with ST-Link ([[https:// | + | |24|Supply voltage out of range| |
- | |32|No communication with IoT device|Leave that rental scooter where it belongs| | + | |26|Flash save error|Try to flash ESC with ST-Link ([[https:// |
- | |35|ESC not activated, has default S/ | + | |27|ESC config invalid|Try to flash ESC with ST-Link ([[https:// |
- | |36|2+4 connector failure or external battery charging wire failure.| | | + | |28|Motor driver mos up-bridge short circuit|Check motor|Hardware error|3| |
- | |37|Charging base failure or built-in battery charging wire failure.| | | + | |29|Motor driver mos down-bridge short circuit|Check motor|Hardware error|3| |
- | |38|Charging overcurrent|Incorrect power supply| | + | |31|Program skip error|Try to flash ESC|System error|3| |
- | |39|Internal battery overheat| | | + | |32|No communication with IoT device|Leave that rental scooter where it belongs|System error|3| |
- | |40|ESC overheat| | | + | |35|ESC not activated, has default S/ |
- | |41|External battery overheat| | | + | |36|2+4 connector failure or external battery charging wire failure.| |
- | |42|No communication with external BMS|Inspect external battery connectors, tighten up external battery screws| | + | |37|Charging base failure or built-in battery charging wire failure.| |
- | |43|External BMS config invalid|Replace external BMS or battery; [[https:// | + | |38|Charging overcurrent|Incorrect power supply|Hardware error|3| |
- | |44|External BMS not activated (has default S/ | + | |39|Internal battery overheat| |
- | |45|Internal BMS deep cell discharge| | | + | |40|ESC overheat| |
- | |46|External BMS deep cell discharge| | | + | |41|External battery overheat| |
- | |49|Internal BMS firmware version mismatch|Change internal BMS firmware version| | + | |42|No communication with external BMS|Inspect external battery connectors, tighten up external battery screws|Hardware error|3| |
- | |50|External BMS firmware version mismatch|Change external BMS firmware version| | + | |43|External BMS config invalid|Replace external BMS or battery; [[https:// |
+ | |44|External BMS not activated (has default S/ | ||
+ | |45|Internal BMS deep cell discharge| | ||
+ | |46|External BMS deep cell discharge| | ||
+ | |48|External battery protection board damaged|Replace external battery or BMS|Hardware error|3| | ||
+ | |49|Internal BMS firmware version mismatch|Change internal BMS firmware version|System warning|2| | ||
+ | |50|External BMS firmware version mismatch|Change external BMS firmware version|System warning|2| | ||