nberrorcodes
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
nberrorcodes [2019/09/28 23:40] – lothean | nberrorcodes [2019/10/27 20:19] – lothean | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== Ninebot ESx/Max Error Codes | + | ====== Ninebot ESx/Max Error Codes ====== |
^Code ^Description | ^Code ^Description | ||
Line 8: | Line 8: | ||
|14|Throttle handle position out of range|Throttle might be stuck, faulty or disconnected| | |14|Throttle handle position out of range|Throttle might be stuck, faulty or disconnected| | ||
|15|Brake handle position out of range|Brake handle might be stuck, faulty or disconnected| | |15|Brake handle position out of range|Brake handle might be stuck, faulty or disconnected| | ||
- | |18|Motor Hall sensors stuck at 0/1|Check 2×4 connector between ESC and motor| | + | |18|Motor Hall sensors stuck at 0/1|Check 2×4 connector between ESC and motor; [[https:// |
|19|Internal battery voltage out of range| | | |19|Internal battery voltage out of range| | | ||
|20|External battery voltage out of range| | | |20|External battery voltage out of range| | | ||
|21|No communication with internal BMS|Check data connector between internal battery and ESC, replace battery| | |21|No communication with internal BMS|Check data connector between internal battery and ESC, replace battery| | ||
- | |22|Internal BMS config invalid|Replace internal BMS or battery| | + | |22|Internal BMS config invalid|Replace internal BMS or battery; [[https:// |
- | |23|Internal BMS not activated (has default S/ | + | |23|Internal BMS not activated (has default S/ |
|24|Supply voltage out of range| | | |24|Supply voltage out of range| | | ||
|26|Flash save error|[[https:// | |26|Flash save error|[[https:// | ||
Line 26: | Line 26: | ||
|41|External battery overheat| | | |41|External battery overheat| | | ||
|42|No communication with external BMS|Inspect external battery connectors, tighten up external battery screws| | |42|No communication with external BMS|Inspect external battery connectors, tighten up external battery screws| | ||
- | |43|External BMS config invalid|Replace external BMS or battery| | + | |43|External BMS config invalid|Replace external BMS or battery; [[https:// |
- | |44|External BMS not activated (has default S/ | + | |44|External BMS not activated (has default S/ |
|45|Internal BMS deep cell discharge| | | |45|Internal BMS deep cell discharge| | | ||
|46|External BMS deep cell discharge| | | |46|External BMS deep cell discharge| | |
nberrorcodes.txt · Last modified: 2022/01/15 01:36 by 127.0.0.1